How-To: Displaying the software version of your F5 product
(SOL914) To display the software version for your F5 product, refer to the article associated with your product in the following table: Product Solution BIG-IP LTM/LTM VE BIG-IP ASM BIG-IP GTM BIG-IP...
View ArticleKnown Issue: The BIG-IP system may incorrectly respond to a recursive query...
(SOL14855) Description The BIG-IP system may incorrectly respond to a recursive query with a non-recursive answer. This issue occurs when all of the following conditions are met: The BIG-IP system is...
View ArticleKnown Issue: A standby BIG-IP system may not update connection information...
(SOL14431) Description A standby BIG-IP system may not update connection information for established mirrored connections. This issue occurs when all of the following conditions are met: Your BIG-IP...
View ArticleError Message: Error Message: crit smartd[PID]: Device:...
(SOL14425) Error Message crit smartd[PID]: Device: /dev/<sda|sdb>, <#> Currently unreadable (pending) sectors In this error message, note the following: [PID] is the smartd...
View ArticleInformational: Transport protocol used for BIG-IP connection and persistence...
(SOL7225) The following table shows the transport protocol and port used for the connection and persistence mirroring channel for the BIG-IP LTM 9.x through 11.x software branches. BIG-IP LTM Version...
View ArticleRelease Note: BIG-IP ASM 11.4.1
This release note documents the version 11.4.1 release of BIG-IP Application Security Manager. You can apply the software upgrade to systems running software versions 10.1.0 (or later), or 11.x.
View ArticleRelease Note: BIG-IP ASM 11.4.0
This release note documents the version 11.4.0 release of BIG-IP Application Security Manager. You can apply the software upgrade to systems running software versions 10.1.0 (or later), or 11.x.
View ArticleRelease Note: BIG-IP ASM 11.2.1
This release note documents the version 11.2.1 release of BIG-IP Application Security Manager.
View ArticleKnown Issue: PVA accelerated connections that have been mirrored may timeout...
(SOL14548) Description PVA accelerated connections that have been mirrored may timeout following a failover event. This issue occurs when all of the following conditions are met: The configuration is...
View ArticleKnown Issue: An IP address object in a non-default partition with a non-zero...
(SOL14876) Description After you upgrade your BIG-IP software, IP address objects in non-default administrative partitions with non-zero default Route Domain (RD) IDs may lose their connections. This...
View ArticleInformational: The BIG-IP connection table command output may contain any6...
(SOL7758) When viewing the BIG-IP connection table using the bigpipe or tmsh utilities, the output may contain any6 entries in the server or client sections of the connection table. Because the BIG-IP...
View ArticleKnown Issue: The fallback persistence timeout is global and is updated only...
(SOL11334) If you apply a fallback persistence profile with a custom timeout other than the default 180 seconds, modify the timeout of an existing fallback persistence profile, or replace a fallback...
View ArticleError Message: Error Message: 01340004:3: HA Connection detected dissimilar peer
(SOL13828) Error Message 01340004:3: HA Connection detected dissimilar peer: local npgs <local TMM instance>, remote npgs <remote TMM instance>, local npus <total...
View ArticleHow-To: Optimizing NTLM traffic in BIG-IP 10.x or later
(SOL10477) NT LAN Manager (NTLM) is a technology that uses an encrypted challenge/response protocol to authenticate users over the network. The system requesting authentication performs a calculation...
View ArticleError Message: Error Message: Instance not...
(SOL14889) Error Message Instance not found:/Common/<client|server>ssl In this error message, note the following: <client|server>ssl is the SSL profile type that you want to...
View ArticleChange in Behavior: Change in behavior: The BIG-IP system establishes a...
(SOL14894) Old Behavior In versions 11.3.0 and earlier, the BIG-IP system only maintains a single global connection and persistence mirroring channel. The active BIG-IP system in an HA device group can...
View ArticlePolicy: Advance End of Sale notice for BIG-IP WebAccelerator
(SOL14706) With the availability of BIG-IP AAM, F5 is announcing the End of Sale (EoS) of BIG-IP WebAccelerator, effective October 1, 2014. F5 is providing advance product notification to customers and...
View ArticleInformational: Configuration changes to local traffic objects do not affect...
(SOL13253) Summary When changes are made to most BIG-IP configuration object options, the new parameters or options defined by the configuration change will only apply to new connections that are...
View ArticleOverview: Overview of connection and persistence mirroring (11.x)
(SOL13478) This article applies to BIG-IP 11.x. For information about other versions, refer to the following article: SOL7222: Overview of connection and persistence mirroring (9.x - 10.x) Note: For...
View ArticleHow-To: Replacing multiple strings using a Stream profile
(SOL7027) Note: For more information about the Stream profile, refer to SOL8115: Overview of the Stream profile. The Stream profile allows you the ability to search for a string within a data stream...
View Article